Equivalent Dose and Radiation Weighting FactorDate: 2015-10-07; view: 618. Units of Absorbed Dose The SI unit for absorbed dose is the gray (Gy) and represents an energy absorption of 1 joule per kilogram of absorbing material, i.e.:
The same absorbed dose delivered by different types of radiation may result in different degrees of biological damage to body tissues. The total energy deposited is not the only factor which determines the extent of the damage. The equivalent dose was introduced to take into account the dependence of the harmful biological effects on the type of radiation being absorbed. The equivalent dose is therefore a measure of the risk associated with an exposure to ionising radiation . Risks due to exposures to different radiation types can be directly compared when in terms of equivalent dose. The unit of equivalent dose is the sievert (Sv) and is defined for a given type of radiation by the relationship:
where: The radiation weighting factor is a dimensionless number which depends on the way in which the energy of the radiation is distributed along its path through the tissue. The rate of deposition of energy along the track is known as the Linear Energy Transfer (LET) of the radiation and has units of Radiation with a high LET (such as heavy charged sub-atomic particles) is more likely than radiation with a low LET (such as x-rays or beta particles) to damage the small structures in tissue such as DNA molecules . This is because the energy from high LET radiation is absorbed in a small volume surrounding the trail of dense ionisation produced by this radiation. The radiation weighting factor is directly related to the LET of the radiation as is shown in Fig. 3.1 Table 3.1: Radiation weighting factors for various radiations The use of the radiation weighting factors to calculate the equivalent dose is illustrated in the following examples:
In other words the dose of
For example if a person were to receive
|